physics : class12 Beta Radiation Range : Properties of Beta Radiation : Atoms and Nuclei MCQ Questions and Answers
Practice important
Beta Radiation Range
MCQ questions and answers.
Page 1
of
1
|
10
MCQ Questions
1. A beta source emits electrons with a continuous energy spectrum having an endpoint energy of 2.0 MeV. If the absorber is sufficiently thick to stop even the endpoint electrons, which statement about the observed beta range is correct?
A.
All beta electrons travel exactly the same range because they originate from the same nucleus
B.
The maximum range is determined by the endpoint-energy electrons, while lower-energy electrons have shorter ranges
C.
The minimum range is determined by the endpoint-energy electrons
D.
The beta range is independent of electron energy because beta particles have the same charge
Correct Answer:
The maximum range is determined by the endpoint-energy electrons, while lower-energy electrons have shorter ranges
Explanation:
Beta particles from a radioactive source have a continuous energy distribution. Since the range increases with kinetic energy, the highest-energy, endpoint electrons penetrate the greatest distance and determine the maximum range.
2. A beta beam has a mass range of 0.75 g cm−2 in an absorber. What thickness of an aluminium sheet, whose density is 2.50 g cm−3, would ideally provide this same stopping power?
A.
0.030 cm
B.
0.30 cm
C.
1.88 cm
D.
3.00 cm
Correct Answer:
0.30 cm
Explanation:
The mass thickness is related to geometrical thickness by m = ρx. Thus x = m/ρ = 0.75/2.50 = 0.30 cm. For comparing beta ranges in different materials, mass thickness is more meaningful than geometrical thickness alone.
3. Two beta absorbers have densities 1.0 g cm−3 and 4.0 g cm−3. If the beta particles have the same mass range of 0.80 g cm−2 in both materials, what is the ratio of their required physical thicknesses, low-density material to high-density material?
A.
1:4
B.
1:1
C.
4:1
D.
16:1
Correct Answer:
4:1
Explanation:
Physical thickness is x = Rm/ρ. Therefore, x_low/x_high = ρ_high/ρ_low = 4.0/1.0 = 4, so the required thickness ratio is 4:1.
4. For a beta spectrum, the maximum electron range in air is measured as 3.0 m. If the same endpoint electrons enter a material in which their stopping power per unit mass thickness is effectively the same as in air, what determines the corresponding range in that material?
A.
Only the atomic number of the material, independent of its density
B.
The material density alone, because the physical range scales inversely with density
C.
The beta-particle charge, which changes when the absorber changes
D.
The endpoint energy and the absorber's mass stopping characteristics, with physical range obtained by dividing mass range by density
Correct Answer:
The endpoint energy and the absorber's mass stopping characteristics, with physical range obtained by dividing mass range by density
Explanation:
Beta range is fundamentally related to energy loss per unit mass thickness. For comparable mass stopping characteristics, the mass range is fixed by the endpoint energy, while the physical distance is x = Rm/ρ.
5. A beta source is placed behind an absorber whose thickness is gradually increased. The detected count rate decreases continuously and reaches the background level only at a thickness of 4.2 mm. What does this thickness most directly represent?
A.
The average range of all beta particles
B.
The minimum range of the beta particles
C.
An estimate of the maximum range associated with the highest-energy beta particles
D.
The wavelength of the beta particles in the absorber
Correct Answer:
An estimate of the maximum range associated with the highest-energy beta particles
Explanation:
Because beta emission has a continuous energy spectrum, electrons are stopped progressively as absorber thickness increases. The thickness at which the count rate approaches background corresponds approximately to the maximum range of the most energetic beta particles.
6. A beta emitter has an endpoint energy of 1.5 MeV. Using the empirical relation R = 0.412E^1.265 − 0.0954, where R is in g cm−2 and E is in MeV, what is the approximate maximum mass range?
A.
0.39 g cm−2
B.
0.54 g cm−2
C.
0.72 g cm−2
D.
1.13 g cm−2
Correct Answer:
0.54 g cm−2
Explanation:
Substituting E = 1.5 MeV gives R ≈ 0.412(1.5)^1.265 − 0.0954 ≈ 0.54 g cm−2. This is the estimated maximum mass range corresponding to the endpoint-energy beta electrons.
7. A beta spectrum has an endpoint energy of 2.0 MeV. If the empirical relation R = 0.412E^1.265 − 0.0954 is used, what is the approximate maximum range in aluminium of density 2.70 g cm−3?
A.
0.28 cm
B.
0.41 cm
C.
0.56 cm
D.
1.51 cm
Correct Answer:
0.56 cm
Explanation:
For E = 2.0 MeV, the mass range is approximately 1.51 g cm−2. The physical range in aluminium is x = R/ρ = 1.51/2.70 ≈ 0.56 cm.
8. Two beta sources have endpoint energies of 0.50 MeV and 2.00 MeV. Using R proportional to E^1.265, what is the approximate ratio of their maximum ranges, R2.00/R0.50?
A.
2.00
B.
2.40
C.
5.06
D.
6.32
Correct Answer:
5.06
Explanation:
The energy ratio is 2.00/0.50 = 4. Hence the range ratio is 4^1.265 ≈ 5.06. The range therefore does not increase linearly with energy under this empirical relation.
9. A thin absorber removes the low-energy part of a beta spectrum but transmits many high-energy electrons. Compared with the unfiltered spectrum, what happens to the measured average range of the transmitted beta particles?
A.
It decreases because some electrons have been removed
B.
It remains exactly unchanged because the endpoint energy is unchanged
C.
It increases because the transmitted population is biased toward higher-energy electrons
D.
It becomes equal to the maximum range of the original spectrum
Correct Answer:
It increases because the transmitted population is biased toward higher-energy electrons
Explanation:
A beta absorber preferentially removes lower-energy electrons because they have shorter ranges. The remaining transmitted spectrum is enriched in higher-energy electrons, so its average range increases, although its maximum range need not change.
10. A beta particle and an alpha particle enter the same absorber with equal kinetic energies. Which statement about their ranges is generally correct?
A.
Their ranges are equal because their kinetic energies are equal
B.
The beta particle generally has a much greater range because its smaller mass gives it a much lower stopping power per unit distance in this comparison
C.
The alpha particle always has a greater range because it carries twice the charge magnitude
D.
Their ranges cannot be compared because neither particle loses energy in matter
Correct Answer:
The beta particle generally has a much greater range because its smaller mass gives it a much lower stopping power per unit distance in this comparison
Explanation:
Beta particles are much lighter than alpha particles and generally lose energy less densely along their paths. Consequently, beta radiation is more penetrating and has a substantially greater range than alpha radiation of comparable kinetic energy.
Short Questions and Answers
Practice short questions and answers related to
Beta Radiation Range
.
Short questions are currently unavailable for this page.