Accuracy versus Precision MCQ Questions and Answers
1. A length has a true value of 10.00 cm. Four observations made with instrument P are 9.98 cm, 9.99 cm, 10.01 cm, and 10.02 cm, while four observations made with instrument Q are 10.20 cm, 10.20 cm, 10.21 cm, and 10.20 cm. Which conclusion is correct?
A. Instrument P is both more accurate and more precise than instrument Q
B. Instrument P is more precise, while instrument Q is more accurate
C. Instrument Q is more precise, while instrument P is more accurate
D. Instrument Q is both more accurate and more precise than instrument P
Correct Answer:
Instrument Q is more precise, while instrument P is more accurate
Explanation:
The readings from P are closely distributed around the true value, so P is accurate and reasonably precise. The readings from Q are much closer to one another, making Q more precise, but they are consistently far from the true value, making Q less accurate.
2. A balance gives the following readings for a standard mass whose true value is 50.00 g: 49.99 g, 50.01 g, 50.00 g, and 50.02 g. A second balance gives 50.20 g, 50.20 g, 50.19 g, and 50.20 g. Which statement best describes the balances?
A. The first balance is accurate and precise; the second is precise but not accurate
B. The first balance is precise but not accurate; the second is accurate but not precise
C. Both balances are accurate but not precise
D. Both balances are precise and accurate to the same degree
Correct Answer:
The first balance is accurate and precise; the second is precise but not accurate
Explanation:
The first balance produces closely grouped readings centered near 50.00 g, demonstrating both accuracy and precision. The second produces closely grouped readings but with a systematic offset, so it is precise but inaccurate.
3. Five groups of repeated measurements of a quantity are represented by their mean value and spread. The accepted value is 25.00 units. Which group demonstrates high precision but low accuracy?
A. Mean = 25.01 units, readings widely scattered
B. Mean = 25.00 units, readings widely scattered
C. Mean = 25.40 units, readings tightly clustered
D. Mean = 25.40 units, readings widely scattered
Correct Answer:
Mean = 25.40 units, readings tightly clustered
Explanation:
High precision means the measurements are tightly clustered, while low accuracy means their central value differs significantly from the accepted value. A tightly clustered mean of 25.40 units satisfies both conditions.
4. A student measures a rod five times and obtains 12.31 cm, 12.32 cm, 12.31 cm, 12.32 cm, and 12.31 cm. The calibrated value of the rod is 12.50 cm. What is the most appropriate conclusion?
A. The measurements are accurate but imprecise
B. The measurements are precise but inaccurate
C. The measurements are neither precise nor accurate
D. The measurements are both accurate and precise
Correct Answer:
The measurements are precise but inaccurate
Explanation:
The readings differ very little from one another, indicating high precision. However, they are all significantly below the calibrated value, indicating poor accuracy, likely due to a systematic error.
5. Two thermometers are used to measure a reference temperature of 100.0 °C. Thermometer X repeatedly reads values between 99.9 °C and 100.1 °C, whereas thermometer Y repeatedly reads exactly 98.0 °C. Which statement is correct?
A. X is accurate and precise, while Y is precise but inaccurate
B. X is precise but inaccurate, while Y is accurate and precise
C. Both X and Y are accurate because their readings are repeatable
D. X is inaccurate because its readings are not identical, while Y is accurate
Correct Answer:
X is accurate and precise, while Y is precise but inaccurate
Explanation:
X gives readings close to the reference value with little spread, so it is both accurate and precise. Y gives an identical reading repeatedly, showing precision, but its reading is far from the reference value, showing inaccuracy.
6. A measuring instrument is modified so that every reading increases by 0.50 cm, but the random scatter of repeated readings remains unchanged. What effect does this modification have?
A. It increases precision but decreases accuracy
B. It decreases precision but increases accuracy
C. It changes accuracy but does not change precision
D. It changes precision but does not change accuracy
Correct Answer:
It changes accuracy but does not change precision
Explanation:
Adding the same constant offset shifts all readings relative to the true value, thereby affecting accuracy. Since the separation or scatter among repeated readings remains unchanged, precision is unaffected.
7. An instrument produces readings that are very close to one another but all differ from the accepted value by the same amount. Which type of error is most consistent with this behavior?
A. A large random error causing low precision
B. A systematic error causing high precision but low accuracy
C. No error, because repeatability guarantees accuracy
D. A parallax error causing both high accuracy and low precision
Correct Answer:
A systematic error causing high precision but low accuracy
Explanation:
A systematic error shifts readings consistently in one direction. This preserves their closeness to one another, so precision remains high, but their distance from the accepted value reduces accuracy.
8. The readings from two instruments for a true value of 5.000 m are as follows: Instrument R: 4.98 m, 5.01 m, 5.03 m; Instrument S: 5.20 m, 5.20 m, 5.20 m. Which comparison is valid?
A. R is less accurate and less precise than S
B. R is more precise and more accurate than S
C. R is more accurate, while S is more precise
D. R is more precise, while S is more accurate
Correct Answer:
R is more accurate, while S is more precise
Explanation:
The readings from R are spread out but lie close to the true value on average, so R is more accurate. The identical readings from S show very high precision, but their large offset from 5.000 m makes S inaccurate.
9. A set of measurements has a mean value equal to the accepted value, but the individual readings are widely dispersed. Another set has readings tightly clustered around a value far from the accepted value. Which statement follows?
A. The first set is accurate but not precise, and the second is precise but not accurate
B. The first set is precise but not accurate, and the second is accurate but not precise
C. Both sets are accurate because their mean values are sufficient
D. Both sets are imprecise because neither contains identical readings
Correct Answer:
The first set is accurate but not precise, and the second is precise but not accurate
Explanation:
The first set has a correct average but large scatter, so it is accurate overall but not precise. The second set has little scatter but is centered away from the accepted value, so it is precise but inaccurate.
10. Which change would most directly improve the accuracy of a highly precise instrument without necessarily changing its precision?
A. Calibrating it against a standard reference
B. Increasing the number of decimal places displayed
C. Repeating the same measurement without correction
D. Reducing the spread of readings that are already tightly clustered
Correct Answer:
Calibrating it against a standard reference
Explanation:
Calibration identifies and corrects systematic deviation from the true value, improving accuracy. It need not alter the instrument's repeatability, which is the basis of precision.
Short questions are currently unavailable for this page.